English 中文 日本語 한국어 Русский
NOKOV Showcases Banner

Capturing Motion,
Crafting Stories

Explore Our Case Studies: Transforming Motion into Masterpieces Across Industries

Developing and Validating the Human-Machine Coupling Model for Optimized Exoskeleton Design and Control

Client
South China University of Technology
Capture volume
Application
motion capture, human-machine coupling, exoskeleton robot
Objects
human gait
Equipment used

An accurate human-machine coupling model is very important in exoskeleton research, as it provides the foundation for predicting the direct impacts of an exoskeleton system on the human body, allowing such systems to minimize injuries and energy loss. A proper model may also help optimize the design and performance of exoskeleton systems, making them easier and more comfortable to control.

A research team at the South China University of Technology proposed a new model for human exoskeleton robots. They verified the accuracy of this model’s kinematics calculations through dynamic experiments and applied the model to design a new power-assisted passive exoskeleton system that made an improved optimization of the control curve of electromechanical exoskeletons.

Kinetic Experiments

The research team utilized the NOKOV optical motion capture system to obtain position, speed, acceleration, and other relevant data of each point on various subjects. This data was then input into the model to compute the gait data and the reaction force of the ground during the double support stage. Data was collected through the implementation of the force plate measuring the point at which both feet made contact with the ground. A comparison was made between the data calculated by the model and the force plate data in order to indirectly verify the accuracy of the model's kinematic calculations.

Optical motion capture system and force measurement platform

Optical motion capture system and force measurement platform

Kinematic double-support stage recognition experiment plot

Kinematic double-support stage recognition experiment plot

Design and control optimization of the exoskeleton robot

After establishing the theoretical model, the lower limb exoskeleton robot was designed and optimized based on the model. A set of passive multi-cooperative exoskeleton prototypes were developed and tested through metabolic experiments. The experiment verified the effectiveness of the exoskeleton in terms of energy consumption. Results showed that on average, human metabolism was reduced by 4.40% while wearing the passive exoskeleton, validating its design.

Passive multi-synergistic exoskeleton experimental prototype

Passive multi-synergistic exoskeleton experimental prototype

Furthermore, an experiment was conducted to optimize the output force of the electromechanical exoskeleton. By inputting a control curve into the hip-mounted exoskeleton, the force curve output was compared to analyze its ability to reduce energy consumption in the human body. The results showed a 1.38% reduction in human metabolism on average, indicating the effectiveness of the hip-mounted electromechanical exoskeleton in reducing energy consumption.

Experiment with hip electromechanical exoskeleton robot and metabolic tester

Experiment with hip electromechanical exoskeleton robot and metabolic tester

Bibliography:

Research on Human-Machine Coupling Model and Its Application in the Design of Lower Limb Exoskeleton

Prev
Applications of motion capture systems in wire-driven continuum robot research
Next
Efficient Trajectory Planning for Continuum Robots (based on RRT*)

NOKOV Motion Capture Basketball Game Demo

UMI Game
2022-03-29

Kung Fu Motion Capture Performance

Shu-Gu Entertainment
2023-02-06

Applications of motion capture systems in wire-driven continuum robot research

Sichuan University
2022-06-17

Suture Skills Learning of Surgical Robot Based on Learning from Demonstration

Chongqing University of Posts and Telecommunications
2022-02-11

By using this site, you agree to our terms, which outline our use of cookies. CLOSE ×

Contact us
We are committed to responding promptly and will connect with you through our local distributors for further assistance.
Engineering Virtual Reality Movement Sciences Entertainment
I would like to receive a quote
Beijing NOKOV Science & Technology Co., Ltd (Headquarter)
LocationRoom820, China Minmetals Tower, Chaoyang Dist., Beijing
Emailinfo@nokov.cn
Phone+ 86-10-64922321
Capture Volume*
Objective*
Full Bodies Drones/Robots Others
Quantity
Camera Type
Pluto1.3C Mars1.3H Mars2H Mars4H Underwater Others/I do not know
Camera Count
4 6 8 12 16 20 24 Others/I don't know